10
20
Product specification
General Purpose & High Cap.
X7R
Surface-Mount Ceramic Multilayer Capacitors
6.3 V to 50 V
ELECTRICAL CHARACTERISTICS
X7R DIELECTRIC CAPACITORS; NISN TERMINATIONS
Unless otherwise specified, all test and measurements shall be made under standard atmospheric conditions
for testing as given in 5.3 of IEC 60068-1:
- Temperature: 15 °C to 35 °C
- Relative humidity: 25% to 75%
- Air pressure: 86 kPa to 106 kPa
Before the measurements are made, the capacitor shall be stored at the measuring temperature for a time
sufficient to allow the entire capacitor to reach this temperature.
The period as prescribed for recovery at the end of a test is normally sufficient for this purpose.
Table 7
VALUE
DESCRIPTION
Capacitance range
100 pF to 22 µF
Capacitance tolerance
Dissipation factor (D.F.)
±5%, ±10%, ±20%
47pF ≤ 0201 ≤ 10nF
100pF ≤ 0402 ≤ 100nF 100pF ≤ 0603 ≤ 1µF
≤ 10 V
≤ 5%
150pF ≤ 0805 ≤ 2.2µF 220 pF ≤ 1206 ≤ 2.2µF 2.2nF ≤ 1210 ≤ 2.2µF
0805 = 4.7 µF
≤ 10%
Exception: 220nF≤ 0402 ≤470nF 0603 = 2.2µF
1206 = 4.7µF
0805 = 10µF
4.7µF≤ 1210 ≤47µF
10 µF ≤ 1206 ≤22µF
≤ 15%
≤ 3.5%
47 pF≤ 0201 ≤1.2nF
100 pF≤ 0402 ≤22nF
100 pF≤ 0603 ≤100nF
2.2nF≤ 1210 ≤1µF
16 V
150 pF≤ 0805 ≤560nF 220pF≤ 1206 ≤1µF
Exception: 1.5 nF≤ 0201 ≤10nF
27nF ≤ 0402 ≤100nF 220 nF ≤ 0603 ≤1µF
≤ 5%
≤ 10%
≤ 2.5%
≤ 3.5%
≤ 5%
680 nF≤ 0805 ≤2.2µF 1206 = 2.2 µF
2.2µF ≤ 1210 ≤10 µF
4.7 µF≤ 0805 ≤10µF
0402 = 220 nF
220nF≤ 0603 ≤1µF
4.7µF ≤ 1206 ≤ 10µF 1210 = 22µF
47pF ≤ 0201 ≤ 470pF
150pF ≤ 0805 ≤ 180nF
100pF ≤ 0402 ≤ 10nF
220pF ≤ 1206 ≤ 680nF
100pF ≤ 0603 ≤39nF
2.2nF≤ 1210 ≤1µF
25 V
Exception: 12 nF ≤ 0402 ≤ 47nF 47nF ≤ 0603 ≤220nF 220nF≤ 0805 ≤560 nF
1206 = 1µF
560pF≤ 0201 ≤10nF
1206 = 2.2µF
56 nF≤ 0402 ≤100 nF 680nF ≤ 0805 ≤1µF
2.2µF ≤ 1210 ≤10 µF
1206 ≥ 4.7µF
≤ 10%
≤ 2.5%
≤ 3.5%
≤ 3.0%
≤ 5%
≥ 50 V
Exception: 020 1 ≥47pF
1206 ≥1µF
0603 ≥47nF
470nF≥ 0805 ≥330 nF
100nF≥ 0402 ≥12nF
0805 ≥1µF
≤ 10%
Insulation resistance after 1 minute at Ur (DC)
Rins ≥ 10 GΩ or Rins × Cr ≥ 500 seconds whichever is less
Maximum capacitance change as a function of temperature
(temperature characteristic/coefficient):
±15%
Operating temperature range:
–55 °C to +125 °C
NOTE
Capacitance tolerance ±5% is not available for full product range, please contact local sales force before ordering
www.yageo.com
Feb. 20, 2013 V.9