Product specification
17
18
Mid-voltage
NP0/X7R 100 V to 630 V
Surface-Mount Ceramic Multilayer Capacitors
TEST
TEST METHOD
4.13
PROCEDURE
REQUIREMENTS
Damp Heat
No visual damage after recovery
1. Preconditioning, class 2 only:
150 +0/-10 °C /1 hour, then keep for
24 ±1 hour at room temp
∆C/C
Class 1:
2. Initial measure:
Spec: refer initial spec C, D, IR
NP0: within ±2% or 1 pF, whichever is greater
Class2:
3. Damp heat test:
500 ±12 hours at 40 ±2 °C;
90 to 95% R.H.
X7R: ±15%
D.F.
Class 1:
4. Recovery:
NP0: ≤ 2 x specified value
Class2:
Class 1: 6 to 24 hours
Class 2: 24 ±2 hours
X7R: ≥ 25 V: ≤ 5%
5. Final measure: C, D, IR
Rins
P.S. If the capacitance value is less than the
minimum value permitted, then after the other
measurements have been made the capacitor shall
be precondition according to “IEC 60384 4.1” and
then the requirement shall be met.
Class 1:
NP0: ≥ 2,500 MΩ or Rins x Cr ≥ 25s whichever
is less
Class2:
X7R: ≥ 500 MΩ or Rins x Cr ≥ 25s whichever is
less
Endurance
IEC 60384- 4.14
21/22
1. Preconditioning, class 2 only:
150 +0/-10 °C /1 hour, then keep for
24 ±1 hour at room temp
No visual damage
∆C/C
2. Initial measure:
Spec: refer initial spec C, D, IR
Class1:
NP0: within ±2% or 1 pF, whichever is greater
3. Endurance test:
Temperature: NP0/X7R: 125 °C
Specified stress voltage applied for 1,000 hours:
Class2:
X7R: ±15%
D.F.
4. High voltage series follows with below stress
condition:
Class1:
Applied 2.0 x Ur for 100 V series
Applied 1.5 x Ur for 200/250 V series
Applied 1.3 x Ur for 500 V, 630 V series
Applied 1.2 x Ur for 1 KV, 2 KV, 3 KV series
NP0: ≤ 2 x specified value
Class2:
X7R: ≥ 25 V: ≤ 5%
Rins
5. Recovery time: 24 ±2 hours
6. Final measure: C, D, IR
Class1:
NP0: ≥ 4,000 MΩ or
Rins x Cr ≥ 40s whichever is less
P.S. If the capacitance value is less than the
minimum value permitted, then after the other
measurements have been made the capacitor shall
be precondition according to “IEC 60384 4.1” and
then the requirement shall be met.
Class2:
X7R: ≥ 1,000 MΩ or
Rins x Cr ≥ 50s whichever is less
Specified stress voltage applied for 1~5 seconds
Voltage Proof
4.6
No breakdown or flashover
Ur ≤ 100 V: series applied 2.5 Ur
100 V < Ur ≤ 200 V series applied
(1.5 Ur + 100)
200 V < Ur ≤ 500 V series applied
(1.3 Ur + 100)
Ur > 500 V: 1.3 Ur
Ur ≧ 1000 V: 1.2 Ur
Charge/Discharge current is less than 50 mA
www.yageo.com