P Series Data Sheet
100 - 195 Watt DC-DC Converters
Output 1
Output 2
Output 3
Output 4
Type
Input voltage
21.6 - 50.4 VDC
Vo nom Po nom Po max
Vo nom Po nom Po max
Vo nom Po nom Po max
Vo nom Po nom Po max
[VDC] [W]
[W]
[VDC] [W]
[W]
[VDC] [W]
[W]
[VDC] [W]
[W]
3.3
5.1
100
122
132
183
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
GP 1101-7R
GP 1001-7R
3.3
5.1
12
15
24
50
61
60
60
60
66
91
96
97
96
5.1
5.1
12
15
24
61
61
60
60
60
91
91
96
97
96
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
GP 2101-7R
GP 2001-7R
GP 2320-7R
GP 2540-7R
GP 2660-7R
5.1
5.1
5.1
61
61
61
91
91
91
12
15
24
30
30
30
48
48
48
12
15
24
30
30
30
48
48
48
-
-
-
-
-
-
-
-
-
GP 3020-7R
GP 3040-7R
GP 3060-7R
5.1
12
15
24
20
30
30
30
30
48
48
48
12
12
15
24
30
30
30
30
48
48
48
48
12
12
15
24
30
30
30
30
48
48
48
48
3.3
12
15
24
10
30
30
30
20
48
48
48
GP 4720-7R
GP 4320-7R
GP 4540-7R
GP 4660-7R
Input
Input voltage
refer to selection chart
Output
Efficiency
Nominal output current Io1,2,3,4 nom
Maximal output current Io1,2,3,4 max
Voltage setting accuracy 1, 2
Voltage setting accuracy 3, 4
Vi nom, Io nom
up to 92%
Po1,2,3,4 nom/Vo1,2,3,4 nom
Po1,2,3,4 max/Vo1,2,3,4
up to 0.6% Vo1,2 nom
2% Vo3,4 nom
Vi nom, Io nom
Vi nom, Io nom
Worst case output voltage 1, 2 Vi min to Vi max, 0 to Io1,2 max, TC min to TC max
1.6% Vo nom
Minimum output current 1, 4
in parallel configuration not required
in individual or series configuration
in parallel configuration not required
in individual or series configuration
Io1,4 min to Io1,4 max
0 A
5% Io1,4 nom
0 A
5% Io2,3 nom
Minimum output current 2, 3
Cross load reg. output 4
Cross load reg. output 3
Output voltage switching noise IEC/EN 61204, total, peak-peak
typ. 100 mΩ • (Io1–Io4)
typ. 100 mΩ • (Io2–Io3)
typ. 0.4% Vo nom
typ. 130% Po max/2
typ. 130% Po max/2
Io2,3 min to Io2,3 max
Common power limitation
(Po1 + Po4) rectangular U/I characteristic
(Po2 + Po3) rectangular U/I characteristic
Protection
Input reverse polarity
Input undervoltage lockout
Input overvoltage lockout
Input transient protection
Output
built-in fuse
typ. 90% Vi min
typ. 110% Vi max
varistor
no-load, overload and short-circuit proof
transient suppressor or 2nd control loop
switch-off with auto restart
Output overvoltage
Overtemperature
typ. 125% Vo nom
TC typ. 100°C
Control
Output voltage adjustment
Inhibit on primary side
Status indication
output 1, 4 (with feature R)
TTL input, output disabled if left open-circuit
LEDs: In OK, Out OK
60 - 110% Vo nom
Output good signal (Out OK)
isolated open-collector signal
Safety
Approvals
EN 60950, UL 1950, CSA C22.2 No. 950
Class of equipment
Protection degree
Electric strength test voltage
class I
IP 40
2100 VDC
2100 VDC
500 V DC
I/case, I/O, I/aux
O/case, aux/case
O/O, O/aux
MAR 25, 2004 revised to JUL 27, 2006
Page 2 of 5
www.power-one.com