产品型号B59870C80A70的Datasheet PDF文件预览

PTC thermistors for  
overcurrent protection  
Leaded disks, coated, 230 V  
Series/Type:  
B598**  
Date:  
June 2011  
© EPCOS AG 2011. Reproduction, publication and dissemination of this publication, enclosures hereto and the  
information contained therein without EPCOS' prior express consent is prohibited.  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
Applications  
Dimensional drawing  
Overcurrent protection  
Short circuit protection  
Features  
Lead-free terminals  
Manufacturer's logo and type designation  
stamped on in black or red for Tref = 80 °C  
and for Tref = 120 °C and 130 °C stamped on  
in white  
Short response times  
UL approval for Tref = 130 °C to UL 1434 with  
Vmax = 220 V and VR = 220 V  
(file number E69802)  
UL approval for Tref = 120 °C to UL 1434 with  
Vmax = 230 V and VR = 220 V  
(file number E69802)  
Dimensions (mm)  
Tref  
Type  
wmax  
hmax  
d
°C  
UL approval for Tref = 80 °C to UL 1434 with  
Vmax = 165 V and VR = 145 V  
(file number E69802)  
VDE approval (license number 104843 E)  
RoHS-compatible  
C810  
C830  
C830  
C830  
C840  
C840  
C840  
C850  
C850  
C850  
C860  
C860  
C860  
C870  
C870  
C870  
C872  
C873  
C874  
C875  
C880  
C880  
C880  
C883  
C890  
C890  
130  
80  
120  
130  
80  
120  
130  
80  
120  
130  
80  
120  
130  
80  
120  
130  
120  
120  
120  
120  
80  
22.0  
22.0  
22.0  
17.5  
17.5  
17.5  
13.5  
13.5  
13.5  
11.0  
11.0  
11.0  
9.0  
9.0  
9.0  
6.5  
9.0  
9.0  
9.0  
9.0  
6.5  
25.5  
25.5  
25.5  
21.0  
21.0  
21.0  
17.0  
17.0  
17.0  
14.5  
14.5  
14.5  
12.5  
12.5  
12.5  
10.0  
12.5  
12.5  
12.5  
12.5  
10.0  
10.0  
7.5  
0.8  
0.6  
0.6  
0.8  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.5  
0.5  
Options  
Leadless disks and leaded disks without  
coating available on request  
Thermistors with diameter w 11.0 mm are  
also available on tape (to IEC 60286-2)  
Delivery mode  
Cardboard strips (standard)  
Cardboard tape reeled or in Ammo pack on  
request  
120  
130  
120  
80  
6.5  
4.0  
6.5  
4.0  
10.0  
7.5  
7.5  
120  
4.0  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 2 of 16  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
General technical data  
Max. operating voltage  
Rated voltage  
Switching cycles  
Tolerance of RR  
Tolerance of RR  
(TA = 60 °C)  
Vmax  
VR  
N
265  
230  
100  
±25  
±20  
V DC or V AC  
V DC or V AC  
(Tref = 80 °C or 120 °C) RR  
(Tref = 130 °C)  
(V = 0)  
%
%
RR  
Top  
Top  
Operating temperature range  
Operating temperature range  
40/+125 °C  
0/+60 °C  
(V = Vmax  
)
Electrical specifications and ordering codes  
IR  
IS  
ISmax  
(V = Vmax  
Ir  
Tref RR  
(typ.)  
Rmin  
Type  
Approvals Ordering code  
)
(typ.)  
(V = Vmax  
mA  
)
mA mA  
A
°C  
C810 650 980  
C830 460 920  
C830 450 680  
C840 330 660  
C840 330 500  
C830 250 510  
C850 200 400  
C850 200 320  
C840 170 350  
C860 140 280  
C860 140 230  
C850 110 230  
C870 100 200  
C870 100 150  
C860 90 180  
C872 80 160  
C873 70 140  
C870 60 130  
C874 60 125  
C875 55 110  
C880 55 110  
7.0  
7.0  
4.1  
4.1  
2.2  
7.0  
2.2  
1.5  
4.1  
1.5  
1.0  
2.2  
1.0  
0.4  
1.5  
1.0  
1.0  
1.0  
1.0  
1.0  
0.4  
0.2  
0.4  
0.4  
0.2  
0.2  
20  
20  
15  
15  
13  
15  
13  
10  
10  
10  
9
8
9
6
6
9
9
5
9
130  
120  
130  
120  
130  
80  
120  
130  
80  
120  
130  
80  
120  
130  
80  
120  
120  
80  
120  
120  
120  
130 160  
120 120  
80  
3.5  
3.7  
5
6
9
3.7  
10  
13  
6
15  
25  
10  
25  
50  
15  
35  
45  
25  
55  
65  
70  
2.3  
2.4  
3.3  
3.8  
5.9  
2.2  
6.4  
8.6  
3.6  
9
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
B59810C0130A070  
B59830C0120A070  
B59830C0130A070  
B59840C0120A070  
B59840C0130A070  
B59830C0080A070  
B59850C0120A070  
B59850C0130A070  
B59840C0080A070  
B59860C0120A070  
B59860C0130A070  
B59850C0080A070  
B59870C0120A070  
B59870C0130A070  
B59860C0080A070  
B59872C0120A070  
B59873C0120A070  
B59870C0080A070  
B59874C0120A070  
B59875C0120A070  
B59880C0120A070  
B59880C0130A070  
B59883C0120A070  
B59880C0080A070  
B59890C0120A070  
B59890C0080A070  
16.5  
6
15  
33  
7.8  
21  
27  
13  
31  
36  
39  
106  
67  
36.7  
84  
78.7  
X
X
X
X
X
X
X
9
6
5
5
4
5
3
C880 55  
C883 35  
C880 30  
C890 30  
C890 15  
90  
70  
70  
60  
40  
70  
120 150  
80 150  
X
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 3 of 16  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
Reliability data  
Test  
Standard  
Test conditions  
R25/R25ꢁ  
Electrical endurance, IEC 60738-1  
cycling  
Room temperature, ISmax; Vmax  
Number of cycles: 100  
< 25%  
Electrical endurance, IEC 60738-1  
constant  
Storage at Vmax /Top,max (Vmax  
Test duration: 1000 h  
)
< 25%  
< 10%  
Damp heat  
IEC 60738-1  
IEC 60738-1  
IEC 60738-1  
Temperature of air: 40 °C  
Relative humidity of air: 93%  
Duration: 56 days  
Test according to IEC 60068-2-78  
Rapid change  
of temperature  
T1 = Top,min (0 V), T2 = Top,max (0 V)  
Number of cycles: 5  
Test duration: 30 min  
< 10%  
Test according to IEC 60068-2-14, Test Na  
Vibration  
Frequency range: 10 to 55 Hz  
Displacement amplitude: 0.75 mm  
Test duration: 3 × 2 h  
< 5%  
Test according to IEC 60068-2-6, Test Fc  
Shock  
IEC 60738-1  
IEC 60738-1  
Acceleration: 390 m/s2  
Pulse duration: 6 ms; 6 × 4000 pulses  
< 5%  
Climatic sequence  
Dry heat: T = Top,max (0 V)  
Test duration: 16 h  
< 10%  
Damp heat first cycle  
Cold: T = Top,min (0 V)  
Test duration: 2 h  
Damp heat 5 cycles  
Tests performed according to  
IEC 60068-2-30  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 4 of 16  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
Characteristics (typical) for Tref = 80 °C  
PTC resistance RPTC versus  
PTC current IPTC versus PTC voltage VPTC  
PTC temperature TPTC  
(measured at 25 °C in still air)  
(measured at low signal voltage)  
Switching time tS versus switching current IS  
(measured at 25 °C in still air)  
Rated current IR versus ambient temperature TA  
(measured in still air)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 5 of 16  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
Characteristics (typical) for Tref = 80 °C  
PTC resistance RPTC versus  
PTC current IPTC versus PTC voltage VPTC  
PTC temperature TPTC  
(measured at 25 °C in still air)  
(measured at low signal voltage)  
Switching time tS versus switching current IS  
(measured at 25 °C in still air)  
Rated current IR versus ambient temperature TA  
(measured in still air)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 6 of 16  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
Characteristics (typical) for Tref = 120 °C  
PTC resistance RPTC versus  
PTC current IPTC versus PTC voltage VPTC  
PTC temperature TPTC  
(measured at 25 °C in still air)  
(measured at low signal voltage)  
Switching time tS versus switching current IS  
(measured at 25 °C in still air)  
Rated current IR versus ambient temperature TA  
(measured in still air)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 7 of 16  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
Characteristics (typical) for Tref = 120 °C  
PTC resistance RPTC versus  
PTC current IPTC versus PTC voltage VPTC  
PTC temperature TPTC  
(measured at 25 °C in still air)  
(measured at low signal voltage)  
Switching time tS versus switching current IS  
(measured at 25 °C in still air)  
Rated current IR versus ambient temperature TA  
(measured in still air)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 8 of 16  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
Characteristics (typical) for Tref = 120 °C  
PTC resistance RPTC versus  
PTC current IPTC versus PTC voltage VPTC  
PTC temperature TPTC  
(measured at 25 °C in still air)  
(measured at low signal voltage)  
Switching time tS versus switching current IS  
(measured at 25 °C in still air)  
Rated current IR versus ambient temperature TA  
(measured in still air)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 9 of 16  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
Characteristics (typical) for Tref = 130 °C  
PTC resistance RPTC versus  
PTC current IPTC versus PTC voltage VPTC  
PTC temperature TPTC  
(measured at 25 °C in still air)  
(measured at low signal voltage)  
Switching time tS versus switching current IS  
(measured at 25 °C in still air)  
Rated current IR versus ambient temperature TA  
(measured in still air)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 10 of 16  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
Characteristics (typical) for Tref = 130 °C  
PTC resistance RPTC versus  
PTC current IPTC versus PTC voltage VPTC  
PTC temperature TPTC  
(measured at 25 °C in still air)  
(measured at low signal voltage)  
Switching time tS versus switching current IS  
(measured at 25 °C in still air)  
Rated current IR versus ambient temperature TA  
(measured in still air)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 11 of 16  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
Cautions and warnings  
General  
EPCOS thermistors are designed for specific applications and should not be used for purposes  
not identified in our specifications, application notes and data books unless otherwise agreed  
with EPCOS during the design-in-phase.  
Ensure suitability of thermistor through reliability testing during the design-in phase. The ther-  
mistors should be evaluated taking into consideration worst-case conditions.  
Storage  
Store thermistors only in original packaging. Do not open the package before storage.  
Storage conditions in original packaging: storage temperature 25 °C ... +45 °C, relative hu-  
midity 75% annual mean, maximum 95%, dew precipitation is inadmissible.  
Avoid contamination of thermistors surface during storage, handling and processing.  
Avoid storage of thermistor in harmful environment with effect on function on long-term opera-  
tion (examples given under operation precautions).  
Use thermistor within the following period after delivery:  
Through-hole devices (housed and leaded PTCs): 24 months  
Motor protection sensors, glass-encapsulated sensors and probe assemblies: 24 months  
Telecom pair and quattro protectors (TPP, TQP): 24 months  
Leadless PTC thermistors for pressure contacting: 12 months  
Leadless PTC thermistors for soldering: 6 months  
SMDs in EIA sizes 3225 and 4032, and for PTCs with metal tags: 24 months  
SMDs in EIA sizes 0402, 0603, 0805 and 1210: 12 months  
Handling  
PTCs must not be dropped. Chip-offs must not be caused during handling of PTCs.  
Components must not be touched with bare hands. Gloves are recommended.  
Avoid contamination of thermistor surface during handling.  
Soldering (where applicable)  
Use rosin-type flux or non-activated flux.  
Insufficient preheating may cause ceramic cracks.  
Rapid cooling by dipping in solvent is not recommended.  
Complete removal of flux is recommended.  
Standard PTC heaters are not suitable for soldering.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 12 of 16  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
Mounting  
Electrode must not be scratched before/during/after the mounting process.  
Contacts and housing used for assembly with thermistor have to be clean before mounting. Es-  
pecially grease or oil must be removed.  
When PTC thermistors are encapsulated with sealing material, the precautions given in chapter  
"Mounting instructions", "Sealing and potting" must be observed.  
When the thermistor is mounted, there must not be any foreign body between the electrode of  
the thermistor and the clamping contact.  
The minimum force of the clamping contacts pressing against the PTC must be 10 N.  
During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent  
components are placed at a sufficient distance from the thermistor to allow for proper cooling at  
the thermistors.  
Ensure that adjacent materials are designed for operation at temperatures comparable to the  
surface temperature of thermistor. Be sure that surrounding parts and materials can withstand  
this temperature.  
Avoid contamination of thermistor surface during processing.  
Operation  
Use thermistors only within the specified temperature operating range.  
Use thermistors only within the specified voltage and current ranges.  
Environmental conditions must not harm the thermistors. Use thermistors only in normal at-  
mospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas, am-  
monia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions. Contact with any  
liquids and solvents should be prevented.  
Be sure to provide an appropriate fail-safe function to prevent secondary product damage  
caused by abnormal function (e.g. use VDR for limitation of overvoltage condition).  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 13 of 16  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
Symbols and terms  
A
Area  
Cth  
f
Heat capacity  
Frequency  
I
Current  
Imax  
IR  
IPTC  
Ir  
Maximum current  
Rated current  
PTC current  
Residual currrent  
Ir,oil  
Ir,air  
IRMS  
IS  
Residual currrent in oil (for level sensors)  
Residual currrent in air (for level sensors)  
Root-mean-square value of current  
Switching current  
ISmax  
LCT  
N
Maximum switching current  
Lower category temperature  
Number (integer)  
Nc  
Operating cycles at Vmax, charging of capacitor  
Switching cycles at Vmax, failure mode  
Power  
Nf  
P
P25  
Pel  
Pdiss  
RG  
Rmin  
RR  
RR  
RP  
RPTC  
Rref  
RS  
R25  
R25,match  
R25  
T
Maximum power at 25 °C  
Electrical power  
Dissipation power  
Generator internal resistance  
Minimum resistance  
Rated resistance  
Tolerance of RR  
Parallel resistance  
PTC resistance  
Reference resistance  
Series resistance  
Resistance at 25 °C  
Resistance matching per reel/ packing unit at 25 °C  
Tolerance of R25  
Temperature  
t
Time  
TA  
Ambient temperature  
Thermal threshold time  
Ferroelectric Curie temperature  
ta  
TC  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 14 of 16  
Overcurrent protection  
Leaded disks, coated, 230 V  
C810 ... C890  
tE  
Settling time (for level sensors)  
TR  
Rated temperature  
Tsense  
Top  
Sensing temperature  
Operating temperature  
TPTC  
tR  
PTC temperature  
Response time  
Tref  
Reference temperature  
TRmin  
tS  
Temperature at minimum resistance  
Switching time  
Tsurf  
Surface temperature  
UCT  
V or Vel  
VRMS  
VBD  
Upper category temperature  
Voltage (with subscript only for distinction from volume)  
Root-mean-square value of voltage  
Breakdown voltage  
Vins  
Insulation test voltage  
Vlink,max  
Vmax  
Vmax,dyn  
Vmeas  
Vmeas,max  
VR  
Maximum link voltage  
Maximum operating voltage  
Maximum dynamic (short-time) operating voltage  
Measuring voltage  
Maximum measuring voltage  
Rated voltage  
VPTC  
Voltage drop across a PTC thermistor  
α
Temperature coefficient  
Tolerance, change  
Dissipation factor  
δth  
τth  
λ
Thermal cooling time constant  
Failure rate  
Lead spacing (in mm)  
Abbreviations / Notes  
Surface-mount devices  
* To be replaced by a number in ordering codes, type designations etc.  
+ To be replaced by a letter  
All dimensions are given in mm.  
The commas used in numerical values denote decimal points.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 15 of 16  
Important notes  
The following applies to all products named in this publication:  
1. Some parts of this publication contain statements about the suitability of our products for  
certain areas of application. These statements are based on our knowledge of typical re-  
quirements that are often placed on our products in the areas of application concerned. We  
nevertheless expressly point out that such statements cannot be regarded as binding  
statements about the suitability of our products for a particular customer application.  
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar  
with them than the customers themselves. For these reasons, it is always ultimately incum-  
bent on the customer to check and decide whether an EPCOS product with the properties de-  
scribed in the product specification is suitable for use in a particular customer application.  
2. We also point out that in individual cases, a malfunction of electronic components or  
failure before the end of their usual service life cannot be completely ruled out in the  
current state of the art, even if they are operated as specified. In customer applications  
requiring a very high level of operational safety and especially in customer applications in  
which the malfunction or failure of an electronic component could endanger human life or  
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by  
means of suitable design of the customer application or other action taken by the customer  
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by  
third parties in the event of malfunction or failure of an electronic component.  
3. The warnings, cautions and product-specific notes must be observed.  
4. In order to satisfy certain technical requirements, some of the products described in this  
publication may contain substances subject to restrictions in certain jurisdictions (e.g.  
because they are classed as hazardous). Useful information on this will be found in our Ma-  
terial Data Sheets on the Internet (www.epcos.com/material). Should you have any more de-  
tailed questions, please contact our sales offices.  
5. We constantly strive to improve our products. Consequently, the products described in this  
publication may change from time to time. The same is true of the corresponding product  
specifications. Please check therefore to what extent product descriptions and specifications  
contained in this publication are still applicable before or when you place an order. We also  
reserve the right to discontinue production and delivery of products. Consequently, we  
cannot guarantee that all products named in this publication will always be available. The  
aforementioned does not apply in the case of individual agreements deviating from the fore-  
going for customer-specific products.  
6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver-  
sion of the "General Terms of Delivery for Products and Services in the Electrical In-  
dustry" published by the German Electrical and Electronics Industry Association  
(ZVEI).  
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap,  
DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKK, MKD, MLSC, MotorCap, PCC,  
PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap,  
SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trade-  
marks registered or pending in Europe and in other countries. Further information will be  
found on the Internet at www.epcos.com/trademarks.  
Page 16 of 16  
配单直通车
B59870T0060B110产品参数
型号:B59870T0060B110
是否无铅: 不含铅
是否Rohs认证: 符合
生命周期:Active
包装说明:,
Reach Compliance Code:compliant
ECCN代码:EAR99
HTS代码:8533.40.80.70
风险等级:5.81
JESD-609代码:e3
制造商序列号:B59870
安装特点:THROUGH HOLE MOUNT
端子数量:3
最高工作温度:125 °C
最低工作温度:-25 °C
封装形状:RECTANGULAR PACKAGE
包装方法:TRAY
额定(AC)电压(URac):230 V
电阻:3.5 Ω
电阻器类型:PTC THERMISTOR
表面贴装:NO
端子面层:Tin (Sn)
端子形状:WIRE
热敏电阻器应用:DEGAUSSING
Base Number Matches:1
  •  
  • 供货商
  • 型号 *
  • 数量*
  • 厂商
  • 封装
  • 批号
  • 交易说明
  • 询价
批量询价选中的记录已选中0条,每次最多15条。
 复制成功!