产品型号B84143D0016R127的Datasheet PDF文件预览

3–line filters  
for converters and power electronics  
530/305 V, 50/60 Hz, 16 ...200 A, 50 °C  
Ordering code:  
Date:  
B84143D0xxxR127  
2007–03–29  
03  
Version:  
EPCOS AG 2007. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the  
information contained therein without EPCOS’ prior express consent is prohibited.  
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Construction  
S 3–line filter  
S Metal case  
S Book size  
Features  
S High insertion loss  
S Optimized for long cable  
S Easy to install  
S Low weight  
S Compact design  
S Degree of protection IP 20 1)  
S Design complies with  
EN 60939, UL 1283, CSA 22.2 No.8  
S Optimized for long motor cable  
and operation under full load  
EN 55011, Class A & B  
Applications  
S Frequency converters for motor drives, e.g.  
– elevators  
– pumps  
– traction systems  
– conveyor systems  
– HVAC systems (heating, ventilation and air conditioning)  
S Power supplies  
S Textile machines  
Terminals  
S Line side: finger–save terminal blocks  
S Load side: finger–save terminal blocks  
Marking  
S Marking on component:  
manufacturer’s logo, ordering code, rated voltage, rated current,  
rated temperature, climatic category, date code  
S Minimum marking on packaging: manufacturer’s logo, ordering code,  
date code, quantity  
1
) To IEC 60529:2001  
Please read Important notes and Cautions and  
warnings at the end of this document.  
P
a
g
e
2
o
f
1
7
B
8
4
1
4
3
D
0
x
x
x
R
1
2
7
-
0
3
-
7
6
5
9
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Typical circuit diagram  
B84143D0016R127 – B84143D0035R127:  
LINE  
LOAD  
L1’  
L2’  
L3’  
L1  
L2  
L3  
PE  
B84143D0050R127 – B84143D0200R127:  
LINE  
LOAD  
L1  
L2  
L3  
L1’  
L2’  
L3’  
PE  
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 3 o f 1 7  
B
8
4
1
4
3
D
0
x
x
x
R
1
2
7
-
0
3
-
7
6
5
9
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Technical data and measuring conditions  
Rated voltage  
UR  
530/305  
50/60  
2200  
2700  
50  
V AC  
Hz  
Rated frequency  
fR  
Test voltage line to line for 2 s  
Test voltage line to case for 2 s  
Rated temperature  
Utest  
Utest  
TR  
V DC  
V DC  
°C  
Overload capability (thermal)  
for 3 min per hour or  
for 30 s per hour  
1.5 x IR  
2.5 x IR  
Climatic category (IEC 60068–1)  
25/100/21  
Typical motor cable length to comply with DIN EN 55011 (2003)  
Ordering code  
IR  
EMC Limits according  
to DIN EN 55011 (2003)1)  
A
class A  
class B  
100m  
100m  
100m  
200m  
200m  
200m  
200m  
200m  
200m  
B84143D0016R127  
B84143D0025R127  
B84143D0035R127  
B84143D0050R127  
B84143D0075R127  
B84143D0090R127  
B84143D0120R127  
B84143D0150R127  
B84143D0200R127  
16  
300m  
300m  
300m  
300m  
300m  
300m  
300m  
300m  
300m  
25  
35  
50  
75  
90  
120  
150  
200  
1): Typical values. The motor cable length depends on the clock frequency and the disturbance level of the frequency converter and migth  
differ from above mentioned indicated cable lenghts. Please note pages 16 and 17.  
Please read Important notes and Cautions and  
warnings at the end of this document.  
P
a
g
e
4
o
f
1
7
B
8
4
1
4
3
D
0
x
x
x
R
1
2
7
-
0
3
-
7
6
5
9
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Characteristics and ordering codes  
2)  
IR  
Terminal Ileak  
cross  
Rtyp  
Approx. Ordering code  
weight  
Approvals  
section  
A
mm2  
mA  
m  
14,5  
7,0  
4,5  
2,5  
1,0  
1,0  
1,0  
0,5  
0,5  
kg  
16  
4
< 37  
< 43  
< 40  
< 55  
< 73  
< 166  
< 166  
< 136  
< 139  
2,5  
B84143D0016R127  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
25  
6
2,5  
B84143D0025R127  
B84143D0035R127  
B84143D0050R127  
B84143D0075R127  
B84143D0090R127  
B84143D0120R127  
B84143D0150R127  
B84143D0200R127  
35  
10  
25  
50  
50  
95  
95  
95  
3,5  
50  
5,5  
75  
8,0  
90  
8,0  
120  
150  
200  
14,5  
17,0  
18,5  
X = in preparation  
2) 3 phase operation in TN network; maximum voltage = U ; frequency = 50 Hz without harmonics; tolerance of capacitors –20%/ 0%; worst  
R
case positioning of the components; unbalance 2% according EN 50160:2000.  
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 5 o f 1 7  
B8 4 1 4 3D 0 xx xR 1 2 7-0 3 -7 6 5 9  
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Dimensional drawings B84143D0016R127  
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 6 o f 1 7  
B8 4 1 4 3D 0 xx xR 1 2 7-0 3 -7 6 5 9  
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Dimensional drawings B84143D0025R127  
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 7 o f 1 7  
B8 4 1 4 3D 0 xx xR 1 2 7-0 3 -7 6 5 9  
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Dimensional drawings B84143D0035R127  
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 8 o f 1 7  
B8 4 1 4 3D 0 xx xR 1 2 7-0 3 -7 6 5 9  
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Dimensional drawings B84143D0050R127  
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 9 o f 1 7  
B8 4 1 4 3D 0 xx xR 1 2 7-0 3 -7 6 5 9  
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Dimensional drawings B84143D0075R127; B84143D0090R127  
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 1 0 o f 1 7  
B8 4 1 4 3D 0 xx xR 1 2 7-0 3 -7 6 5 9  
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Dimensional drawings B84143D0120R127; B84143D0150R127  
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 11 o f 1 7  
B8 4 1 4 3D 0 xx xR 1 2 7-0 3 -7 6 5 9  
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Dimensional drawings B84143D0200R127  
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 1 2 o f 1 7  
B8 4 1 4 3D 0 xx xR 1 2 7-0 3 -7 6 5 9  
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Insertion loss (typical values at Z = 50 W)  
unsymmetrical, adjacent branches terminated  
common mode, all branches in parallel (asymmetrical)  
differential mode (symmetrical)  
B84143D0016R127  
B84143D0025R127  
120  
dB  
120  
dB  
a
a
100  
100  
80  
60  
40  
20  
80  
60  
40  
20  
0
10  
0
10  
6
7
6
7
4
5
4
5
10  
10 Hz  
10  
10 Hz  
10  
10  
f
f
B84143D0035R127  
B84143D0050R127  
120  
dB  
120  
dB  
a
a
100  
100  
80  
60  
40  
20  
80  
60  
40  
20  
0
10  
0
10  
6
7
6
7
4
5
4
5
10  
10 Hz  
10  
10 Hz  
10  
10  
f
f
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 1 3 o f 1 7  
B8 4 1 4 3D 0 xx xR 1 2 7-0 3 -7 6 5 9  
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Insertion loss (typical values at Z = 50 W)  
unsymmetrical, adjacent branches terminated  
common mode, all branches in parallel (asymmetrical)  
differential mode (symmetrical)  
B84143D0075R127  
B84143D0090R127  
120  
dB  
120  
dB  
a
a
100  
100  
80  
60  
40  
20  
80  
60  
40  
20  
0
10  
0
10  
6
7
6
7
4
5
4
5
10  
10 Hz  
10  
10 Hz  
10  
10  
f
f
B84143D0120R127  
B84143D0150R127  
120  
dB  
120  
dB  
a
a
100  
100  
80  
60  
40  
20  
80  
60  
40  
20  
0
10  
0
10  
6
7
6
7
4
5
4
5
10  
10 Hz  
10  
10 Hz  
10  
10  
f
f
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 1 4 o f 1 7  
B
8
4
1
4
3
D
0
x
x
x
R
1
2
7
-
0
3
-
7
6
5
9
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Insertion loss (typical values at Z = 50 W)  
unsymmetrical, adjacent branches terminated  
common mode, all branches in parallel (asymmetrical)  
differential mode (symmetrical)  
B84143D0200R127  
120  
dB  
a
100  
80  
60  
40  
20  
0
10  
6
7
4
5
10  
10 Hz  
10  
f
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 1 5 o f 1 7  
B8 4 1 4 3D 0 xx xR 1 2 7-0 3 -7 6 5 9  
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Caution and warnings  
S Please note the advices in our data book “EMC Filters” (latest edition); attention should  
be paid to the chapter “General safety notes”.  
S It shall be ensured that only qualified persons (electricity specialists) are engaged on work  
such as planning, assembly, installation, operation, repair and maintenance. They must  
be provided with the corresponding documentation.  
S Danger of electric shock. EMC filters contain components that store an electric charge.  
Dangerous voltages can continue to exist at the filter terminals for longer than five min-  
utes even after the power has been switched off.  
S The protective earth connections shall be the first to be made when the EMC filter is  
installed and the last to be disconnected. Depending on the magnitude of the leakage cur-  
rents, the particular specifications for making the protective–earth connection must be ob-  
served.  
S Impermissible overloading of the EMC filter, such as with circuits able to cause reso-  
nances, impermissible voltages at higher frequencies etc. can lead to bodily injury and  
death as well as cause substantial material damages (e.g. destruction of the filter hous-  
ing).  
S EMC filters must be protected in the application against impermissible exceeding of the  
rated currents by overcurrent protective.  
S In case of leakage currents > 3.5 mA you shall mount the PE conductor stationary with  
the required cross section before beginning of operation and save it against disconnect-  
ing. For leakage currents IL 4) < 10 mA the PE conductor must have a KU value 3) of 4.5;  
for leakage currents IL q 10 mA the PE conductor must have a KU value of 6.  
3) The KU value (symbol KU) is a classification parameter of safety–referred failure types designed to ensure protection against hazardous  
body currents and excessive heating.  
A value of KU = 4.5 with respect to interruptions is attained:  
2
– with a permanently connected protective earth circuit w 1.5 mm  
2
– with a protective earth circuit w 2.5 mm connected via shroud connectors (IEC 60309–2).  
2
KU = 6 with respect to interruptions is achieved for fixed–connection lines w 10 mm where the type of connection and line layout corre-  
spond to the requirements for PEN conductors as specified in relevant standards.  
4) I = leakage current let–go  
L
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 1 6 o f 1 7  
B8 4 1 4 3D 0 xx xR 1 2 7-0 3 -7 6 5 9  
3–line filters  
B84143D0xxxR127  
for converters and power electronics  
Important notes  
The following applies to all products named in this publication:  
1. Some parts of this publication contain statements about the suitability of our products for cer-  
tain areas of application. These statements are based on our knowledge of typical requirements  
that are often placed on our products in the areas of application concerned. We nevertheless ex-  
pressly point out that such statement cannot be regarded as binding statements about the suit-  
ability of our products for a particular customer application. As a rule, EPCOS is either unfamil-  
iar with individual customer applications or less familiar with them than the customers themselves.  
For these reasons, it is always ultimately incumbent on the customer to check and decide whether  
an EPCOS product with the properties described in the product specification is suitable for use in  
a particular customer application.  
2. We also point out that in individual cases, a malfunction of passive electronic components or  
failure before end of their usual service life time cannot be completely ruled out in the current  
state of the art, even if they are operated as specified. In customer applications requiring a very  
high level of operational safety and especially in customer applications in which the malfunction or  
failure of a passive electronic component could endanger human life or health (e.g. in accident pre-  
vention or life–saving systems), it must therefore be ensured by means of suitable design of the cus-  
tomer application or other action taken by the customer (e.g. installation of protective circuitry or re-  
dundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure  
of a passive electronic component.  
3. The warnings, cautions and product–specific notes must be observed.  
4. In order to satisfy certain technical requirements, some of the products described in this publica-  
tion may contain substances subject to restrictions in certain jurisdictions (e.g. because they  
are classed as “hazardous”). Useful information on this will be found in our Material Data Sheets  
on the Internet (www.epcos.com/material). Should you have any more detailed questions, please  
contact our sales offices.  
5. We constantly strive to improve our products. Consequently, the products described in this publi-  
cation may change from time to time. The same is true of the corresponding product specifica-  
tions. Please check therefore to what extent product descriptions and specifications contained in  
this publication are still applicable before or when you place an order.  
We also reserve the right to discontinue production and delivery of products. Consequently,  
we cannot guarantee that all products named in this publication will always be available.  
6. Unless otherwise agreed in individual contracts, all orders subject to the current version of the  
“General Terms of Delivery for Products and Services in the Electrical Industry” published  
by the the German Electrical and Electronics Industry Association (ZVEI).  
7. The trade names EPCOS, BAOKE, Alu–X, CeraDiode, CSSP, MLSC, MotorCap, PhaseCap,  
PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, WindCap  
are trademarks registered or pending in Europe and in other countries. Further  
information will be found on the Internet at www.epcos.com/trademarks.  
1
Please read Important notes and Cautions and  
warnings at the end of this document.  
Pa g e 1 7 o f 1 7  
B8 4 1 4 3D 0 xx xR 1 2 7-0 3 -7 6 5 9  
配单直通车
B84143D0016R127产品参数
型号:B84143D0016R127
是否Rohs认证: 符合
生命周期:Active
IHS 制造商:TDK CORP
包装说明:METAL PACKAGE
Reach Compliance Code:not_compliant
风险等级:5.84
认证:UL; CSA; IEC
滤波器类型:THREE PHASE EMI FILTER
高度:150 mm
高电位:2700 V
最大漏电流:37 mA
长度:248 mm
安装类型:PANEL MOUNT
工作频率:50/60Hz Hz
物理尺寸:L248.0XB60.0XH150.0 (mm)/L9.764XB2.362XH5.906 (inch)
额定电流:16 A
额定电压:530 V
宽度:60 mm
  •  