Energy Limiting (BA-BE Series)
CLASS 2
ENERGY LIMITING TRANSFORMERS
•ꢀ Used in chimes, door bells, security systems, decorative
ꢀ lighting,ꢀfurnaces,ꢀhumidifiers,ꢀappliances,ꢀvendingꢀ
machines, intercom system type applications.
•ꢀ Rugged, low noise, cool running design, indoor use only.
•ꢀ Strippedꢀwireꢀinputꢀ(primary)ꢀleads,ꢀscrewꢀterminal/quickꢀfitꢀꢀ
tab terminal output (secondary).
•ꢀ Nipple locknut mount for box installation, complete with
locknut and mounting bracket (as shown below).
•ꢀ Input leads are black, on 240V models 240V lead is red.
All models are 60 Hz.- inherently limited - no fuses or
circuit breakers.
•ꢀ C UL & UL listed #E184371 - EXCEPT for part numbers
BE2F & BE7G.
•ꢀ CSAꢀcertifiedꢀ(#LRꢀ3902ꢀClassꢀ2)ꢀenergyꢀlimitingꢀ
transformer. Complies with CSA standard C22.2 #66 part B
120 Volt Primary
A.C. Output
Secondary
(RMS)
A.C.
Input
(Primary)
V (RMS)
Dimensions
(Inches)
Power
Rating Note
VA
Part No.
V
A
A
B
C
BA2DA
BC2DA
BC2F
BC2G
BD2E
BD2EE
BD2F
BD2FF
BD2G
BE2F
120
120
120
120
120
120
120
120
120
120
120
10
10
16
24
12
14
16
18
24
0.5
1.2
0.75
0.5
1.67
1.43
1.25
1.11
0.833
2.42
1.67
5
*
*
*
*
*
*
*
*
*
*
*
2.33 2.22 1.98
2.33 2.22 1.98
2.33 2.22 1.98
2.33 2.22 1.98
2.33 2.34 1.98
2.33 2.34 1.98
2.33 2.34 1.98
2.33 2.34 1.98
2.33 2.34 1.98
2.33 2.60 1.98
2.33 2.60 1.98
12
12
12
20
20
20
20
20
40
40
16.5
24
BE2G
Notes: * 105 degree temperature design
Other Primary Voltages
A.C. Output
Secondary
(RMS)
A.C.
Input
(Primary)
V (RMS)
Dimensions
(Inches)
Power
Rating Note
VA
Part No.
V
A
A
B
C
BD5F
BD5G
BE5G
BE5DG 208/240
BE7G 347
240
240
240
16
24
24
24
24
1.25
0.83
1.67
1.67
1.67
20
20
40
40
40
*
*
*
*
-
2.33 2.34 1.98
2.33 2.34 1.98
2.33 2.60 1.98
2.33 2.60 1.98
2.33 2.60 1.98
Notes: * 105 degree temperature design
BLK
Primary
(LINE)
Secondary
(LOAD)
BLK
CANADA
EUROPE
Guelph, Ontario (519) 822-2960
St. Laurent, Quebec (514) 343-9010
USA
Basingstoke, UK 01256 812812
www.hammondmfg.com
100
AUSTRALIA
Queenstown, Australia 61-8-8240-2244
Cheektowaga, NY (716) 630-7030
©