Changes to Step #5
Edit by timtom77 —
Edit approved by Spencer Day
- Before
- After
- Unchanged
Step Lines
[title] Measurement | |
- | [* black] Disconnect the |
- | [* black] Use a multimeter to measure the voltages at the |
+ | [* black] Disconnect the main flex cable and connect the charger. |
+ | [* black] Use a multimeter to measure the voltages at the large end pins of the FPC connector of the charging board. (See the second image) |
[* black] If the reading is okay (~5V) continue with the next step, if not - change the Charging board. | |
- | [* black] Attach the |
+ | [* black] Attach the main flex cable and measure the large end pins of the Main flex FPC connector - pic.3. |
[* black] If the reading is okay, continue with the next step, if not - change the Main flex cable. |