PUBLIC NOTICE
Draft Air Quality Permits 6696-R1 through 6698-R1, The George Washington University, Operation of three existing identical 6.0 MMBTU/hr natural gas-fired boilers at South Hall, 2135 F Street NW
Notice is hereby given that, pursuant to 20 DCMR §210, the Air Quality Division (AQD) of the Department of Energy and Environment (DOEE), located at 1200 First Street NE, 5th Floor, Washington, DC, intends to issue Permits (Nos. 6696-R1, 6697-R1 and 6698-R1) to the George Washington University to operate three existing natural gas-fired hot water boilers each rated at 6.0 MMBtu/hr, located at South Hall, 2135 F Street NW, Washington DC. The contact person for the facility is Janine Helwig, Interim Director, Utilities and Engineering, at (202) 994-5141.
The following boilers are to be permitted:
Equipment Location |
Address |
Serial Number |
Boiler ID |
Natural Gas Rating (MMBTU/hr) |
Permit Number |
South Hall |
2135 F St. NW Washington DC |
96525 |
EUN-626, South Hall Boiler #1 |
6.0 |
6696-R1 |
South Hall |
2135 F St. NW Washington DC |
96561 |
EUN-627, South Hall Boiler #2 |
6.0 |
6697-R1 |
South Hall |
2135 F St. NW Washington DC |
96559 |
EUN-628, South Hall Boiler #3 |
6.0 |
6698-R1 |
The proposed emission limits are as follows:
a. Each of the three (3) identical boilers shall not emit pollutants in excess of those specified in the following table [20 DCMR 201]:
Pollutant
|
Short-Term Limit (Natural Gas) (lb/hr) |
Carbon Monoxide (CO) |
0.49 |
Oxides of Nitrogen (NOx) |
0.59 |
Total Particulate Matter (PM Total)1 |
0.045 |
Sulfur Dioxide (SO2) |
0.004 |
Volatile Organic Compounds (VOC) |
0.032 |
1PM Total includes both filterable and condensable fractions.
-
- Visible emissions shall not be emitted into the outdoor atmosphere from the boilers, except that discharges not exceeding forty percent (40%) opacity (unaveraged) shall be permitted for two (2) minutes in any sixty (60) minute period and for an aggregate of twelve (12) minutes in any twenty-four hour (24 hr.) period during start-up, cleaning, adjustment of combustion controls, or malfunction of the equipment [20 DCMR 606.1]
- Total suspended particulate matter (TSP) emissions from the each of the boilers shall not be greater than 0.11 pounds per million BTU. [20 DCMR 600.1].
- An emission into the atmosphere of odorous or other air pollutants from any source in any quantity and of any characteristic, and duration which is, or is likely to be injurious to the public health or welfare, or which interferes with the reasonable enjoyment of life or property is prohibite [20 DCMR 903.1]
- NOx and CO emissions shall not exceed those achieved with the performance of annual combustion adjustments on each boiler. To show compliance with this condition, the Permittee shall, each calendar year, perform adjustments of the combustion processes of the boilers with the following characteristics [20 DCMR 805.1(a)(4) and 805.8(a) and (b)]:
-
-
- Inspection, adjustment, cleaning or replacement of fuel burning equipment, including the burners and moving parts necessary for proper operation as specified by the manufacturer;
-
-
-
- Inspection of the flame pattern or characteristics and adjustments necessary to minimize total emissions of NOx and, to the extent practicable, minimize emissions of CO;
-
-
-
- Inspection of the air-to-fuel ratio control system and adjustments necessary to ensure proper calibration and operation as specified by the manufacturer; and
-
-
-
- Adjustments shall be made such that the maximum emission rate for any contaminant does not exceed the maximum allowable emission rates as set forth in Condition II of this permit.
-
The application to operate the boilers and the draft permits and supporting documents are available for public inspection at AQD and copies may be made available between the hours of 8:15 A.M. and 4:45 P.M. Monday through Friday. Interested parties wishing to view these documents should provide their names, addresses, telephone numbers and affiliation, if any, to Stephen S. Ours at (202) 535-1747.
Interested persons may submit written comments or may request a hearing on this subject within 30 days of publication of this notice. The written comments must also include the person’s name, telephone number, affiliation, if any, mailing address and a statement outlining the air quality issues in dispute and any facts underscoring those air quality issues. All relevant comments will be considered in issuing the final permits.
Comments on the proposed permit and any request for a public hearing should be addressed to:
Stephen S. Ours
Chief, Permitting Branch - Air Quality Division
Department of Energy and Environment
1200 First Street NE, 5th Floor
Washington, DC 20002
No comments or hearing requests submitted after September 24, 2018 will be accepted.
For more information, please contact Stephen S. Ours at (202) 535-1747.